48V 175Ah Sodium-Ion Energy Storage Battery | 8.4kWh Low-Temperature Pack
Quick Specifications
|
Parameter |
Specification |
|
Battery technology |
Rechargeable sodium-ion |
|
Model designation |
48V175Ah |
|
Rated capacity |
175Ah |
|
Nominal voltage |
48V |
|
Calculated nominal energy |
8.4kWh |
|
Charge voltage limit |
57.8V ±0.5V |
|
Discharge cutoff voltage |
40V ±0.5V |
|
Standard charging current |
32A |
|
Maximum continuous charging current |
80A |
|
Standard discharge current |
80A |
|
Maximum continuous discharge current |
100A |
|
Specified charging temperature |
−20°C to +60°C |
|
Specified discharging temperature |
−35°C to +60°C |
|
Dimensions |
890 × 416 × 237mm, ±2mm |
|
Cycle-life specification |
6,000 cycles with more than 80% initial capacity under stated conditions |
Nominal energy is calculated as 48V × 175Ah. It does not represent guaranteed usable AC energy or energy available at the minimum operating temperature.
What Is a 48V 175Ah Sodium-Ion Energy Storage Battery?
A 48V 175Ah sodium-ion energy storage battery is a rechargeable DC battery pack that stores energy using sodium-ion cells. Based on its stated nominal voltage and capacity, this model provides 8.4kWh of nominal stored energy.
It can be evaluated for solar energy storage, inverter-based backup, and remote-site power systems where the electrical interface, operating environment, and required documentation match the project.
This model’s specification lists discharge operation from −35°C to +60°C and charging from −20°C to +60°C. These are separate operating envelopes: permission to discharge at a particular temperature does not automatically permit charging at that temperature.
As a sodium-ion energy storage battery supplier, we assess the battery together with the inverter, charging equipment, load profile, and installation conditions.
What Does Polyanion Sodium-Ion Mean?
Polyanion describes a family of sodium-ion cathode materials, including phosphate-based structures. It is one branch of sodium-ion technology, alongside other cathode families.
The supplied chemistry materials discuss potential advantages in structural stability, cold-weather operation, and cycling performance. Those characteristics must still be verified for the selected cell and finished battery; a chemistry name alone does not establish a pack rating.
Key Features
Separate Low-Temperature Charging and Discharging Ratings
The specification lists a discharge temperature range of −35°C to +60°C and a charging range of −20°C to +60°C, making this model relevant to cold-climate storage projects.
As a low-temperature sodium-ion battery supplier, we evaluate minimum cell temperature, cold-soak duration, load, and charging conditions before confirming suitability. Maximum current should not be assumed available across the entire temperature range without a derating specification.
8.4kWh Nominal Energy for Storage and Backup Planning
The stated 48V nominal voltage and 175Ah capacity provide a calculated nominal energy of 8.4kWh.
As a sodium-ion backup battery supplier, we size the installation around required usable energy, inverter losses, reserve settings, and ambient temperature. This gives buyers a practical basis for runtime planning without confusing nominal battery energy with delivered AC energy.
Defined Charge and Discharge Current Limits
The pack specifies 100A maximum continuous discharge and 80A maximum continuous charging. Standard operating currents are listed as 80A discharge and 32A charge.
As an industrial sodium-ion battery pack supplier, we check these limits against the inverter’s DC demand and charging capability. At 48V nominal, 100A corresponds to approximately 4.8kW DC; this is a reference calculation rather than a constant AC output rating.
A Clearly Stated Cycle-Life Criterion
The datasheet specifies 6,000 cycles with more than 80% of initial capacity, using standard charge and discharge conditions at 20°C ±5°C, with 30-minute rest periods.
As a wholesale 48V sodium-ion battery supplier, we distinguish this specification from completed endurance-test evidence and contractual warranty terms. The separate chemistry slides show ongoing cell cycling results, which should not be presented as a completed 6,000-cycle pack test.
Inverter Integration Based on Actual Voltage Limits
The stated charging limit is 57.8V ±0.5V, with a discharge cutoff of 40V ±0.5V. These values are central to charger selection and inverter commissioning.
As a sodium-ion battery supplier for inverter systems, we review charge settings, shutdown thresholds, restart behavior, and communication requirements. A shared 48V label does not establish compatibility with an existing lead-acid or LiFePO₄ installation.
Defined Dimensions for Installation Planning
The specified enclosure measures 890 × 416 × 237mm, ±2mm, giving installers a starting point for compartment and mounting design.
As a custom sodium-ion battery pack supplier, we assess terminal access, cable routing, service clearance, mechanical support, and environmental exposure. The front-panel display and connection features shown on the 100Ah promotional unit must be confirmed separately for the supplied 175Ah configuration.
Technical Specifications
|
Category |
Parameter |
Specification / Qualification |
|
Identification |
Model |
48V175Ah |
|
Chemistry |
Battery technology |
Sodium-ion |
|
Chemistry |
Exact cathode formulation |
Confirm against selected cell specification |
|
Configuration |
Series count |
Attachment identifies a 17-series configuration; confirm in final assembly documentation |
|
Capacity |
Typical rated capacity |
175Ah |
|
Capacity |
Minimum rated capacity |
≥175Ah under the stated capacity-test procedure |
|
Voltage |
Nominal voltage |
48V |
|
Energy |
Calculated nominal energy |
8.4kWh |
|
Voltage |
Charging limit |
57.8V ±0.5V |
|
Voltage |
Discharge cutoff |
40V ±0.5V |
|
Charging |
Standard charge |
32A constant current, followed by constant voltage to the approved limit |
|
Charging |
Maximum continuous charge |
80A |
|
Discharging |
Standard discharge |
80A |
|
Discharging |
Maximum continuous discharge |
100A |
|
Discharging |
Peak discharge current |
Not specified |
|
Power |
Reference nominal DC discharge power |
Approximately 4.8kW at 48V and 100A |
|
Temperature |
Charging range |
−20°C to +60°C |
|
Temperature |
Discharging range |
−35°C to +60°C |
|
Temperature |
Current derating across temperature range |
Not supplied; confirm before system design |
|
Storage |
Specified storage temperature |
−10°C to +45°C |
|
Storage |
Recommended storage SOC |
30%–50% |
|
Storage |
Maintenance guidance |
Check and recharge approximately every three months to prevent over-discharge |
|
Electrical testing |
Initial AC internal impedance |
≤50mΩ, measured at 1kHz at approximately 50% charge |
|
Cycle life |
Datasheet criterion |
6,000 cycles with >80% initial capacity |
|
Cycle conditions |
Temperature and procedure |
20°C ±5°C; standard charging/discharging; 30-minute rest periods |
|
Mechanical |
Dimensions, L × W × H |
890 × 416 × 237mm, ±2mm |
|
Mechanical |
Weight |
Not specified |
|
Environmental |
IP rating |
Not specified |
|
Integration |
CAN / RS485 protocol |
Confirm for the supplied model |
|
Monitoring |
Display, Bluetooth, or remote monitoring |
Confirm for the supplied model |
|
Expansion |
Parallel operation and maximum unit count |
Not specified |
|
Compliance |
Certificates and reports |
Confirm model coverage and destination requirements |
|
Warranty |
Warranty period |
Not stated; confirm in quotation |
Applications
Cold-Climate Solar Energy Storage
As a sodium-ion solar storage battery supplier, we evaluate this pack for storing energy from a compatible solar charging system and supplying it through an inverter when required.
The specified low-temperature operating ranges make it relevant to cold-region projects, provided charging controls, current derating, enclosure conditions, and inverter settings are confirmed.
Inverter-Based Lead-Acid Replacement
As a sodium-ion battery supplier for lead-acid replacement, we evaluate existing installations for electrical and mechanical compatibility.
Replacement may require revised charging settings, SOC monitoring, wiring, protective devices, or equipment configuration. It should not be described as a universal plug-and-play conversion.
Compact Industrial Forklifts
For forklifts operating within compatible 48V–72V electrical platforms, a sodium-ion forklift battery manufacturer must confirm controller compatibility, hydraulic power demand, compartment fit, and minimum battery weight. The 50Ah–150Ah range must be checked against the required shift duration.
Residential Backup Power
As a residential sodium-ion battery supplier, we assess the pack for essential-load backup systems using a compatible inverter.
Selection depends on actual load power, starting surges, required backup duration, and installation requirements. The 8.4kWh nominal energy figure should be converted into usable AC energy before making runtime commitments.
Remote-Site and Unattended Equipment Power
As a remote-site sodium-ion storage battery supplier, we evaluate projects where low temperatures and limited maintenance access affect battery selection.
Project review should cover standby consumption, seasonal charging availability, low-voltage recovery, monitoring requirements, and environmental protection.
Engineered UPS Integration
As a sodium-ion backup battery supplier, we can assess this configuration for UPS projects whose DC bus and current requirements fit the pack.
Short-duration UPS applications can demand substantial current. The supplied specification does not establish high-rate or peak-current capability beyond its 100A continuous discharge rating.
Small Commercial and Industrial Backup
As an industrial sodium-ion battery pack supplier, we assess the pack for selected control systems, communications equipment, and other compatible DC or inverter-supported loads.
The continuous current limit, load transients, required reliability, and applicable product documentation must be checked before deployment.
LiFePO₄ vs. Sodium-Ion Battery Comparison
This table distinguishes the supplied sodium-ion model from general LiFePO₄ selection considerations. Chemistry-level comparison figures in the slides are not universal product specifications.
|
Comparison Point |
LiFePO₄ Battery |
Supplied 48V175Ah Sodium-Ion Model |
Practical Selection Implication |
|
Cathode family |
Lithium iron phosphate |
Sodium-ion; exact formulation requires confirmation |
Confirm the actual cell model and chemistry |
|
Nominal pack voltage |
Depends on series configuration |
Stated as 48V |
Compare complete voltage windows |
|
Nominal stored energy |
Depends on voltage and capacity |
Calculated at 8.4kWh |
Compare usable energy under equivalent conditions |
|
Discharge temperature |
Model-specific; conventional products may have narrower cold limits |
Datasheet specifies −35°C to +60°C |
Check current and energy available at the required temperature |
|
Charging temperature |
Many conventional products restrict cold charging; heated and specialized designs differ |
Datasheet specifies −20°C to +60°C |
Obtain temperature-dependent charging limits |
|
−40°C operation |
Requires an appropriately qualified design |
Outside this model’s stated discharge range |
Do not transfer the 100Ah promotional claim to this model |
|
Energy density |
Supplied slides list 150–180Wh/kg as a reference |
Slides list 90–110Wh/kg for the compared polyanion cells; pack weight is not supplied |
Cell figures cannot establish finished-pack weight |
|
SOC estimation |
Flat voltage characteristics can complicate voltage-only estimation |
Slides describe a more sloping voltage-capacity relationship |
Accurate SOC still requires calibrated measurement and algorithms |
|
Discharge power |
Cell- and pack-specific |
100A maximum continuous discharge |
Evaluate complete-pack ratings, not general cell C-rates |
|
Cycle life |
Depends on design and test conditions |
6,000-cycle datasheet criterion at 20°C ±5°C |
Compare equivalent test procedures and completed reports |
|
Deep-discharge tolerance |
Operation must remain within approved limits |
Approved cutoff listed as 40V ±0.5V |
Do not use generic zero-volt cell claims as operating instructions |
|
Safety |
Requires electrical, thermal, and mechanical protection |
Also requires protection and finished-system validation |
Avoid absolute fireproof or explosion-proof claims |
|
Charger compatibility |
Requires a suitable LiFePO₄ profile |
Requires approved sodium-ion settings |
Matching voltage labels are insufficient |
|
Lifecycle cost |
Depends on purchase price, throughput, efficiency, and service life |
Requires an actual project quotation and operating assumptions |
No fixed cost-saving percentage is established |
Customization Options
|
Customization Item |
Reference Configuration |
Project Options for Evaluation |
Information Required |
|
Voltage |
48V nominal |
Alternative series configuration |
Inverter operating and charging limits |
|
Capacity |
175Ah |
Alternative capacity or energy target |
Daily energy use and backup duration |
|
Discharge current |
100A maximum continuous |
Higher-current design requiring engineering review |
Continuous demand and surge profile |
|
Charging |
32A standard; 80A maximum continuous |
Charger matching and charging strategy |
Charging source, available power, and charging window |
|
Cold-weather operation |
−35°C discharge; −20°C charge |
Thermal management or a separately qualified lower-temperature design |
Minimum cell temperature and exposure duration |
|
Enclosure |
890 × 416 × 237mm |
Alternative dimensions or mounting arrangement |
Installation drawing and clearance |
|
Connections |
Confirm on supplied model |
Terminal, connector, and cable configuration |
Current rating, cable routing, and connector preference |
|
BMS |
Final configuration to be confirmed |
Protection thresholds, monitoring, and balancing |
Required functions and operating limits |
|
Communication |
Not defined in supplied PDF |
CAN / RS485 integration |
Inverter model and protocol documentation |
|
Local display |
Shown on 100Ah promotional unit only |
Display integration for the quoted configuration |
Required parameters and mounting position |
|
Remote monitoring |
Not established |
Connectivity and software assessment |
Network availability and data requirements |
|
Parallel expansion |
Not established |
Engineered multi-pack system |
Target energy, inverter power, and expansion plan |
|
Environmental protection |
IP rating not stated |
Enclosure sealing and condensation management |
Indoor/outdoor conditions and required protection |
|
OEM branding |
Project-specific |
Labels, packaging, and operating instructions |
Artwork, language, and traceability requirements |
|
Documentation |
Supplied technical specification |
Project-specific tests and destination documentation |
Installation market and requested standards |
Customer FAQ
-
1. How much energy does the 48V175Ah sodium-ion battery store?
-
2. Can this battery operate at −40°C?
-
3. Can this sodium-ion battery charge below freezing?
-
4. How long can the battery power my equipment?
-
5. Can it run a 5kW inverter at full output?
-
6. How long does charging take?
-
7. Does the battery have a verified 6,000-cycle service life?
-
8. Can I reuse my existing lead-acid or LiFePO₄ inverter and charger?
-
9. Can I connect several packs in parallel or use the battery outdoors?
-
10. What information is needed for an accurate quotation?
Battery Testing and Quality Control
Each AOVOLT electric motorcycle lithium battery pack is tested before shipment to support safety, performance consistency and reliable mass production. The testing process helps verify cell quality, BMS protection, voltage accuracy, capacity performance, charge-discharge stability and final packing condition.

Certifications and Compliance
For international B2B orders, AOVOLT can support lithium battery shipping and compliance documents according to product configuration and destination market requirements.
Available documents may include MSDS, RoHS, UN38.3, CE or other project-based documents. Required documents should be confirmed before sample approval or bulk production.
Factory Service
Power upgrade, zero maintenance cost
ODM & OEM Customization, One-stop Solution, Strict Quality Assurance.
inquiry now
Other products
Send inquiry
description2

E-Mobility Battery
Lead Acid Replacement Battery
Drone Battery
Energy Storage System
Industrial & Robot Battery
Custom Battery Pack
Tool Replacement Battery
Electric Mobility Battery
Drone Battery
Energy Storage Battery
Lead-to-Lithium Battery
Robot Battery
Custom Battery Pack
Tool and Garden Tool Battery